Virtual Connect (VC) interconnects reboot during the activation stage of the firmware update process, interrupting server connectivity to these modules. You can minimize the impact of module firmware activation by ensuring a redundant hardware configuration, redundantly connected networks and uplink sets, as well as properly configured NIC teaming on the servers themselves. Hewlett Packard Enterprise recommends using these network design methodologies. When updating HPE FlexFabric interconnects, you must configure SAN connectivity redundantly as well, to avoid application outages.
When designing network connectivity, consider all of the dependencies that can influence the ability of the server applications to continue to pass traffic without interruption during the VC interconnect firmware update process. Verify the following aspects of a redundant design before you update firmware in downtime sensitive environments: